PRODUCTS

E-WALL 157R 200R 215R 229R
Detailed Introduction:

[ overview ] [ Easy to install and maintain ] [ Safe & Reliable ]
Indoor battery holder with IP20protection rating,Built-inlithium battery and BMS Local and remote management, standard rack and moduledesign, front-end maintenance Independently developed Level2 / Level 3 BMS,Compoundprotection, safe and reliable

[ high density ] [ Long service life ] [ Battery balancing ]
LP Large capacity aluminum shelllithium battery, more than 130wh/kg Long cycle life, 6000 cycles Active battery balance and passive batterybalance


Model

E-MATE 157R

E-MATE 200R E-MATE 215R E-MATE 229R

Properties

Battery (Wh/V)

14.336 kWh, 51.2 V, 110 kg (242.5 lbs)

Pack of quantity

11

14 15 16

Cell type

LFP (LiFePO4)

LFP (LiFePO4) LFP (LiFePO4) LFP (LiFePO4)

Energy

157.696 kWh

200.704 kWh 215.04 kWh 229.376 kWh

Nominal Voltage

563.2 V

716.8 V 768.0 V 819.2V

Supply Voltage

501.6-617.76 V

638.4 - 786.24 V 684-898.6 V 729.6-898.5 V

Output Current

140 A / 280 A

140 A / 280 A 140 A / 280 A 140 A / 280 A

Communication

Display

SOC status display, LED light display

Communication

Ethernet / CAN / RS485


Product Parameters

Size(W*D*H)

  1721×840×1776 mm

66.8×33.1×69.9 inch

Weight

1540 kg (3395 lbs)

1870 kg (4122 lbs) 1980 kg (4365 lbs) 2090 kg (4608 lbs)

Operating Temperature Range

-20 to 60 °C (-4 to 140 °F)

Ambient Humidity

≤ 95%RH (No condensation)

IP Rate

IP 20

Service life

6000 cycles @ 80% DOD / 25℃ / 0.5C,60%EOL

Scalability

Yes

Context of Use

Grid-connected/ grid-connected + standby/ off-grid

Compatible inverter

See list of compatible inverters (compatible with major PCS brands)


Order and deliverable parts

Certificate

Cell: UN38.3 / IEC62619 / UL 1642 / JET

Pack: UN38.3 / IEC62619 / IEC61000

System: UL 9540 (More available upon request)


Order and deliverable parts

parts

E-MATE-14.3P-F-OT

E-MATE-BCU-157H1-OT

E-MATE-BCU-200H1-OT E-MATE-BCU-215H1-OT E-MATE-BCU-229H1-OT

E-MATE-R18


1 Test conditions: 100% discharge depth (DoD), charge and discharge at 0.2C at 25°C
2 Charge/discharge derating occurs when the operating temperature is -10°C to 5°C and 45°C to 55°C
3 Please refer to the warranty for applicable conditions




  2025-7-4 9:11:44